Verified against sources (checked 2026-11-19T01:32:47.638Z).
Computed from datasheet Voc (51.90V), Vmp (44.00V), and βVoc (-0.241%/°C): cold morning (−10 °C) Voc = 56.28V/mod, hot afternoon (+55 °C cell) Vmp = 39.66V/mod.
| Inverter DC Bus | Min Modules / String | Max Safe Modules / String |
|---|---|---|
| 600 V Residential | 4 | 10 |
| 1000 V Commercial | 6 | 17 |
| 1500 V Utility | 14 | 26 |
What this entry publishes
2 of 8 key fields- Rated power450 Wp
- Module efficiency22.17%
- Cell technologyNot published
- DimensionsNot published
- WeightNot published
- Product warrantyNot published
- Power guaranteeNot published
- DatasheetNot linked
Missing fields are shown as not published rather than estimated. Check the manufacturer datasheet to confirm them.
SunPower SPR-A450-COM
SunPower SPR-A450-COM: 450 Wp · Monocrystalline · monofacial · 22.17% STC efficiency. Specs verified from manufacturer datasheet.
22.17% module efficiency
Warranty unpublished (scored as lowest tier)
Priced capacity unpublished
2 recognized certs
Methodology 2026.10-v1 · Verified 2026-11-19T01:32:47.638Z · Ranked, not sponsored
- Certifications: None of INMETRO Portaria 140, IEC 61215, ABNT NBR 16690 found in published specs — confirm with the datasheet.
- Grid interconnection: ABNT NBR 16149 / ANEEL REN 1.059/2023
- Legal register: In Force · permits 15 - 34 days with local Concessionária (Enel, CPFL, Light)
Register merge of jurisdiction, policy, and legal-seed data. Unmatched items stay unverified — confirm with the datasheet and local authority before purchase.
Dual Electrical Specifications: STC vs NMOT
Standard Test Conditions (1000 W/m², 25°C, AM1.5) vs Nominal Operating Conditions (800 W/m², 20°C, 1 m/s wind)
| Electrical Parameter | STC Laboratory | NMOT Field Conditions | Unit |
|---|---|---|---|
| Maximum Peak Power (Pmax) | 450 | 340 | Wp |
| Voltage at Maximum Power (Vmp) | 34.62 | 32.37 | V |
| Current at Maximum Power (Imp) | 13 | 10.5 | A |
| Open-Circuit Voltage (Voc) | 41.96 | 39.53 | V |
| Short-Circuit Current (Isc) | 13.68 | 11.01 | A |
| Module Conversion Efficiency | 22.17% | 20.8% | % |
Module performance degrades at elevated cell temperatures. N-Type TOPCon and HJT exhibit lower power loss in hot tropical climates compared to legacy PERC modules.
Certified resistance to hurricane-force wind loads, heavy snow pressure, and ice hailstone impacts.
String Sizing & MPPT Safety Verification Tool
Calculates safe series string length based on extreme winter low and summer high ambient temperatures.
Field Electrical & Connector Specs
Authorized Regional Distributors & Stockists
Official Tier-1 trade partners holding local pallet and container stocks for SunPower in Brazil.
O maior distribuidor de energia solar fotovoltaica para Geração Distribuída (GD) do Brasil e América Latina.
Specifications
Electrical, mechanical and temperature specifications as listed for this entry.
| Nominal Power (Pmax) | 450 Wp |
| Module Efficiency | 22.17 % |
| Temp. Coeff. (Pmax) | -0.329 %/°C |
| Power Density | 221.7 Wp/m² |
| Max Power Voltage (Vmp) | 44 V |
| Max Power Current (Imp) | 10.2 A |
| Open Circuit Voltage (Voc) | 51.9 V |
| Short Circuit Current (Isc) | 11 A |
| NOCT | 48 °C |