Skip to main content
SolarQna
Back to panels

Curated entry, not yet verified.

Entered by hand. Specifications and compliance flags have not been checked against a manufacturer source yet.

Target Jurisdiction:
🇧🇷 Brazil:INMETRO (Instituto Nacional de Metrologia)
Key Standards: INMETRO Portaria 140 • IEC 61215 • ABNT NBR 16690Grid Code: PRODIST Módulo 3 / ANEEL

What this entry publishes

7 of 8 key fields
  • Rated power440 Wp
  • Module efficiency22.5%
  • Cell technologyHPBC
  • Dimensions1722 × 1134 × 30 mm
  • Weight20.8 kg
  • Product warranty25 years
  • Power guarantee25 years
  • DatasheetNot linked

Missing fields are shown as not published rather than estimated. Check the manufacturer datasheet to confirm them.

Residential Full Black ModuleNot yet verified
HPBC Cell MatrixSingle Glass
Dimensions: 1722 × 1134 × 30 mmWeight: 20.8 kg

Hi-MO X6 Explorer LR5-54HTH 440W

Premium residential front-busbar-free HPBC cell architecture delivering sleek aesthetic all-black finish and exceptional low-light yield.

Independent score76/100
Performance21/25

22.5% module efficiency (HPBC)

Durability25/25

25-year product warranty, 25-year performance

Value25/25

$0.13/W from stored price estimate

Compliance5/25

no certifications published · ALMM

Methodology 2026.10-v1 · Not yet verified — scores use unconfirmed catalogue data · Ranked, not sponsored

Compliance check
Partial — see gaps
  • Certifications: None of INMETRO Portaria 140, IEC 61215, ABNT NBR 16690 found in published specs — confirm with the datasheet.
  • Grid interconnection: ABNT NBR 16149 / ANEEL REN 1.059/2023
  • Legal register: In Force · permits 15 - 34 days with local Concessionária (Enel, CPFL, Light)

Register merge of jurisdiction, policy, and legal-seed data. Unmatched items stay unverified — confirm with the datasheet and local authority before purchase.

STC Peak Power440 Wp
Module Efficiency22.5%
30-Yr OutputNot verified
Wholesale Est. (BRL)R$ 0,74/Wp
🇧🇷 INMETRO Selo ALei 14.300 / GD AprovadoIEC 61215 & IEC 61730

Dual Electrical Specifications: STC vs NMOT

Standard Test Conditions (1000 W/m², 25°C, AM1.5) vs Nominal Operating Conditions (800 W/m², 20°C, 1 m/s wind)

Not yet calibrated
Electrical ParameterSTC (estimated)NMOT (estimated)Unit
Maximum Peak Power (Pmax)440332Wp
Voltage at Maximum Power (Vmp)33.8531.65V
Current at Maximum Power (Imp)1310.49A
Open-Circuit Voltage (Voc)41.0338.65V
Short-Circuit Current (Isc)13.6811.01A
Module Conversion Efficiency22.5%21.1%%

Vmp, Imp, Voc and Isc are estimated from Pmax using standard module ratios until the datasheet is checked.

Thermal Temperature Coefficients

Module performance degrades at elevated cell temperatures. N-Type TOPCon and HJT exhibit lower power loss in hot tropical climates compared to legacy PERC modules.

γ (Pmax)-0.34%/°CPower Coefficient
β (Voc)-0.25%/°CVoltage Coefficient
α (Isc)+0.045%/°CCurrent Coefficient
Tropical Climate Advantage:At a cell temperature of 65°C (+40°C above STC), this panel retains 86.4% of rated output.
Mechanical & Structural Durability

Mechanical limits below are not yet confirmed against a certificate for this entry.

Front Mechanical Load (Snow)Not verified
Rear Mechanical Load (Wind)Not verified
Hailstone Impact ResistanceNot verified
Junction Box & ProtectionNot verified
Max System VoltageNot verified

String Sizing & MPPT Safety Verification Tool

Calculates safe series string length based on extreme winter low and summer high ambient temperatures.

IEC 62548 Standard
Raises Voc (Risk of overvoltage)
Lowers Vmp (Risk of dropout)
Usually 1000V or 1100V
Usually 160V to 200V
Max Cold Voc per Module44.62 VAt -10°C ambient
Min Hot Vmp per Module28.67 VAt 70°C cell temperature
Recommended String Range7 – 22 PanelsPrevents winter overvoltage and summer MPPT dropout

Field Electrical & Connector Specs

Connector TypeMC4-EVO2 Compatible
Output Cable Length1200 mm (4.0 mm²)
Max Series Fuse Rating30 A
Fire Safety ClassClass C (UL 790) / Type 1

Authorized Regional Distributors & Stockists

Official Tier-1 trade partners holding local pallet and container stocks for LONGi Solar in Brazil.

View All Global Distributors
🇧🇷Aldo Solar Brasil
HQ: Maringá, Paraná, Brasil
Tier-1 Global

O maior distribuidor de energia solar fotovoltaica para Geração Distribuída (GD) do Brasil e América Latina.

Hubs: Centro de Distribuição Maringá, PR (30.000 m²), Hub Logístico Recife, PE, Depósito Avançado São Paulo, SP
Line Card & Contact
🇧🇷Fortlev Solar
HQ: Serra, Espírito Santo, Brazil
National Master

One of Brazil's largest solar equipment distributors, leveraging national manufacturing presence to support distributed generation.

Hubs: Serra, ES, Itatiba, SP, Camaçari, BA
Line Card & Contact

Specifications

Electrical, mechanical and temperature specifications as listed for this entry.

Nominal Power (Pmax)440 Wp
Module Efficiency22.50 %
Temp. Coeff. (Pmax)-0.29 %/°C
Max Power Voltage (Vmp)33.88 V
Max Power Current (Imp)12.99 A
Open Circuit Voltage (Voc)40.09 V
Short Circuit Current (Isc)13.91 A
Front Glass3.2 mm Coated Tempered Glass

Hardware Compatibility & String Inverter Pairing

Test All Inverters in Simulator→

Each listed inverter is electrically validated below from published specs — string windows, failures, and unverifiable gaps shown as-is. Cold design −10°C, hot design 60°C.

Validated inverters:
Enphase IQ8+ MicroinverterCannot fully verify

No verified window

  • UNVERIFIED — Cold Voc vs max DC: Cannot verify — inverter max DC input voltage unpublished.
  • PASS — Hot Vmp vs MPPT floor: Vmp at 60°C ≈ 30.4 V/panel → min 1 in series for the 25 V MPPT floor.
  • UNVERIFIED — String current: Cannot verify — panel Isc unpublished or no valid string window.
  • ASSUMPTION — No Voc-specific temperature coefficient published — Pmax coefficient (-0.29%/°C) used as proxy.
  • ASSUMPTION — Cold design -10°C, hot design 60°C. Confirm against the datasheet for your site.

No verified window

  • PASS — Cold Voc vs max DC: Voc at -10°C ≈ 36.0 V/panel → max 13 in series under 480 V.
  • UNVERIFIED — Hot Vmp vs MPPT floor: Cannot verify — inverter MPPT range unpublished.
  • PASS — String current: String current ≈ Isc 13.91 A — confirm against the inverter's per-MPPT current limit in the datasheet.
  • ASSUMPTION — No Voc-specific temperature coefficient published — Pmax coefficient (-0.29%/°C) used as proxy.
  • ASSUMPTION — Cold design -10°C, hot design 60°C. Confirm against the datasheet for your site.