Verified against sources (checked 2026-11-18T23:52:41.241Z).
Computed from datasheet Voc (44.50V), Vmp (38.20V), and βVoc (-0.234%/°C): cold morning (−10 °C) Voc = 48.14V/mod, hot afternoon (+55 °C cell) Vmp = 35.23V/mod.
| Inverter DC Bus | Min Modules / String | Max Safe Modules / String |
|---|---|---|
| 600 V Residential | 5 | 12 |
| 1000 V Commercial | 6 | 20 |
| 1500 V Utility | 16 | 31 |

What this entry publishes
8 of 8 key fields- Rated power380 Wp
- Module efficiency20.7%
- Cell technologyHJT
- Dimensions1767 × 1041 × 35 mm
- Weight19.7 kg
- Product warranty25 years
- Power guarantee25 years
- DatasheetLinked
Meyer Burger MB_B120AyB_380
Meyer Burger MB_B120AyB_380: 380 Wp · HJT · monofacial · 20.70% STC efficiency · 25-yr product warranty. Specs verified from manufacturer datasheet.
20.7% module efficiency (HJT)
25-year product warranty, 25-year performance
Priced capacity unpublished
2 recognized certs
Methodology 2026.10-v1 · Verified 2026-11-18T23:52:41.241Z · Ranked, not sponsored
- Certifications: Matches 1/3 required: IEC 61215
- Grid interconnection: ABNT NBR 16149 / ANEEL REN 1.059/2023
- Legal register: In Force · permits 15 - 34 days with local Concessionária (Enel, CPFL, Light)
Register merge of jurisdiction, policy, and legal-seed data. Unmatched items stay unverified — confirm with the datasheet and local authority before purchase.
Verified Retailer & Distributor Stock
Live inventory prices tracked across certified wholesale & retail solar suppliers.
No live retail listings currently matched for this specific model.
Our web crawler monitors 220+ verified solar shops. You can request direct supplier quotes or check our global equipment offers catalog.
Dual Electrical Specifications: STC vs NMOT
Standard Test Conditions (1000 W/m², 25°C, AM1.5) vs Nominal Operating Conditions (800 W/m², 20°C, 1 m/s wind)
| Electrical Parameter | STC Laboratory | NMOT Field Conditions | Unit |
|---|---|---|---|
| Maximum Peak Power (Pmax) | 380 | 287 | Wp |
| Voltage at Maximum Power (Vmp) | 29.23 | 27.33 | V |
| Current at Maximum Power (Imp) | 13 | 10.5 | A |
| Open-Circuit Voltage (Voc) | 35.43 | 33.38 | V |
| Short-Circuit Current (Isc) | 13.68 | 11.01 | A |
| Module Conversion Efficiency | 20.7% | 19.5% | % |
Module performance degrades at elevated cell temperatures. N-Type TOPCon and HJT exhibit lower power loss in hot tropical climates compared to legacy PERC modules.
Certified resistance to hurricane-force wind loads, heavy snow pressure, and ice hailstone impacts.
String Sizing & MPPT Safety Verification Tool
Calculates safe series string length based on extreme winter low and summer high ambient temperatures.
Field Electrical & Connector Specs
Authorized Regional Distributors & Stockists
Official Tier-1 trade partners holding local pallet and container stocks for Meyer Burger in Brazil.
O maior distribuidor de energia solar fotovoltaica para Geração Distribuída (GD) do Brasil e América Latina.
Specifications
Electrical, mechanical and temperature specifications as listed for this entry.
| Nominal Power (Pmax) | 380 Wp |
| Module Efficiency | 20.70 % |
| Temp. Coeff. (Pmax) | -0.259 %/°C |
| Power Density | 206.6 Wp/m² |
| Max Power Voltage (Vmp) | 38.2 V |
| Max Power Current (Imp) | 10 A |
| Open Circuit Voltage (Voc) | 44.5 V |
| Short Circuit Current (Isc) | 10.6 A |
| Max System Voltage | 1000 V DC |
| NOCT | 44 °C |
| Annual Degradation | 0.25 %/yr |
| Connector | MC4 / MC4-Evo2 / UKT Energy PV-CO02 / TE Connectivity PV4-S1 (depends on variant y) |
| Junction Box | IP68 |