Verified against sources (checked 2026-11-18T23:52:41.241Z).
Computed from datasheet Voc (40.60V), Vmp (33.90V), and βVoc (-0.260%/°C): cold morning (−10 °C) Voc = 44.29V/mod, hot afternoon (+55 °C cell) Vmp = 30.44V/mod.
| Inverter DC Bus | Min Modules / String | Max Safe Modules / String |
|---|---|---|
| 600 V Residential | 5 | 13 |
| 1000 V Commercial | 7 | 22 |
| 1500 V Utility | 19 | 33 |

What this entry publishes
8 of 8 key fields- Rated power360 Wp
- Module efficiency19.7%
- Cell technologyMono PERC
- Dimensions1755 × 1040 × 30 mm
- Weight19.5 kg
- Product warranty25 years
- Power guarantee25 years
- DatasheetLinked
Panasonic EVPV360PK
Panasonic EVPV360PK: 360 Wp · PERC · monofacial · 19.70% STC efficiency · 25-yr product warranty. Specs verified from manufacturer datasheet.
19.7% module efficiency (Mono PERC)
25-year product warranty, 25-year performance
Priced capacity unpublished
2 recognized certs
Methodology 2026.10-v1 · Verified 2026-11-18T23:52:41.241Z · Ranked, not sponsored
- Certifications: Matches 1/3 required: IEC 61215
- Grid interconnection: ABNT NBR 16149 / ANEEL REN 1.059/2023
- Legal register: In Force · permits 15 - 34 days with local Concessionária (Enel, CPFL, Light)
Register merge of jurisdiction, policy, and legal-seed data. Unmatched items stay unverified — confirm with the datasheet and local authority before purchase.
Dual Electrical Specifications: STC vs NMOT
Standard Test Conditions (1000 W/m², 25°C, AM1.5) vs Nominal Operating Conditions (800 W/m², 20°C, 1 m/s wind)
| Electrical Parameter | STC Laboratory | NMOT Field Conditions | Unit |
|---|---|---|---|
| Maximum Peak Power (Pmax) | 360 | 272 | Wp |
| Voltage at Maximum Power (Vmp) | 27.69 | 25.89 | V |
| Current at Maximum Power (Imp) | 13 | 10.51 | A |
| Open-Circuit Voltage (Voc) | 33.56 | 31.61 | V |
| Short-Circuit Current (Isc) | 13.68 | 11.01 | A |
| Module Conversion Efficiency | 19.7% | 18.5% | % |
Module performance degrades at elevated cell temperatures. N-Type TOPCon and HJT exhibit lower power loss in hot tropical climates compared to legacy PERC modules.
Certified resistance to hurricane-force wind loads, heavy snow pressure, and ice hailstone impacts.
String Sizing & MPPT Safety Verification Tool
Calculates safe series string length based on extreme winter low and summer high ambient temperatures.
Field Electrical & Connector Specs
Authorized Regional Distributors & Stockists
Official Tier-1 trade partners holding local pallet and container stocks for Panasonic in Brazil.
O maior distribuidor de energia solar fotovoltaica para Geração Distribuída (GD) do Brasil e América Latina.
Specifications
Electrical, mechanical and temperature specifications as listed for this entry.
| Nominal Power (Pmax) | 360 Wp |
| Module Efficiency | 19.70 % |
| Temp. Coeff. (Pmax) | -0.340 %/°C |
| Power Density | 197.2 Wp/m² |
| Max Power Voltage (Vmp) | 33.9 V |
| Max Power Current (Imp) | 10.62 A |
| Open Circuit Voltage (Voc) | 40.6 V |
| Short Circuit Current (Isc) | 11.26 A |
| Max System Voltage | 1000 V DC |
| NOCT | 44 °C |
| Annual Degradation | 0.5 %/yr |
| Connector | Stäubli MC4 PV-KBT4/KST4 (IEC 62852, IP68 only when connected) |
| Junction Box | IP67 |