Thermal Derating & NOCT Simulation
Heat Yield Comparison — How Much Power Do Panels Lose in the Heat?
Solar panels produce less electricity as their cells heat up in strong summer sunlight. Compare operating cell temperatures, percentage power drops, and actual Watts delivered between high-temperature HJT, TOPCon, and PERC modules.
Environmental Conditions
Set real ambient weather and mounting airflow
Ambient Air Temperature35 °C
10°C (Cool)25°C (STC)35°C (Summer)50°C (Desert)
Sunlight Irradiance (G)1000 W/m²
Thermal Comparison (3 Modules)
Pick modules to compare thermal resilience side-by-side
HJT
MY Solar MS740N-HJTGB
Temp Coeff: -0.24%/°C
Operating Cell Temp:74 °C
Thermal Output Loss:-11.76%
Net Power Output:653 W
Drop from 740 W STC rating
Back Contact
AIKO-A805-GRH78Dw
Temp Coeff: -0.26%/°C
Operating Cell Temp:74 °C
Thermal Output Loss:-12.74%
Net Power Output:702.4 W
Drop from 805 W STC rating
Back Contact
AIKO-A795-GRH78Dw
Temp Coeff: -0.26%/°C
Operating Cell Temp:74 °C
Thermal Output Loss:-12.74%
Net Power Output:693.7 W
Drop from 795 W STC rating
Physics Insight: Heterojunction (HJT) vs TOPCon vs Mono PERC
Heterojunction modules (such as Panasonic HIT Kuro at -0.26%/°C) retain significantly more power on scorching summer roofs (60°C–70°C cell temp) compared to standard Mono PERC (-0.35%/°C). Over a 25-year lifetime in hot climates (Middle East, Southern US, India, Australia), this 0.09%/°C advantage yields thousands of extra kilowatt-hours.